Matrox Radient eCL     
Camera Interface Application Note
  
IO Industries Flare 4M180‐CL                   
July 23, 2013
 
 
 
Camera Descriptions 
Basics about the camera 
Effective resolution: up to 2050 
×
 2048 
×
 10‐bit @ 179.7 fps. 
Camera Link FULL interface (Eight or Ten taps). 
Progressive scan. 
Internal sync. 
External or internal exposure control. 
80 MHz pixel clock rate. 
 
Mode of operations as per  
Matrox Imaging (in parentheses 
as per camera manufacturer)
 
Interface Mode 
Continuous  
Pseudo‐continuous  
Asynchronous reset (Edge‐Triggered, Level‐controlled Exposure) 
 
Camera Interface Briefs 
Basics about the interface modes 
Mode 1: Continuous 
 
Up to 2050 
×
 2048 
×
 10‐bit @ 179.7 fps. 
Camera Link FULL interface (Eight or Ten taps). 
Matrox Radient eCL receiving LVAL, FVAL, PCLK and video from camera. 
DCF used: 
 
DCF used: 
 
 
 
 
Mode 2: Pseudo‐continuous 
 
2050 
×
 2048 
×
 10‐bit. 
Camera Link FULL interface (Eight or Ten taps). 
Matrox Radient eCL sending TIMER1 OUT (CC1) signal to camera to initiate and 
control the exposure. 
Matrox Radient eCL receiving LVAL, FVAL, PCLK and video from camera. 
DCF used: 
 
DCF used: 
 
 
RAD‐CID‐025 
Page 1 
 
 Matrox Radient eCL     
Camera Interface Application Note
  
IO Industries Flare 4M180‐CL                   
July 23, 2013
 
 
Basics about the interface modes 
Camera Interface Briefs (cont.) 
Mode 2: Pseudo‐continuous 
 
VIDEO
LVAL
FVAL
PCLK
EXP1 (CC1)
 
Matrox
Radient eCL
(RAD2GxF...*)
IO Industries
Flare 4M180-CL
 
Mode 3: Asynchronous reset
 
 
2050 
×
 2048 
×
 10‐bit. 
Camera Link FULL interface (Eight or Ten taps). 
Matrox Radient eCL receiving external trigger signal. 
Matrox Radient eCL sending TIMER1 OUT (CC1) signal to camera to initiate and 
control the exposure. 
Matrox Radient eCL receiving LVAL, FVAL, PCLK and video from camera. 
DCF used: 
 
DCF used: 
 
 
 
 
 
 
 
 
 
 
 
RAD‐CID‐025 
Page 2 
 
 Matrox Radient eCL     
Camera Interface Application Note
  
IO Industries Flare 4M180‐CL                   
July 23, 2013
 
 
Camera Interface Details 
Specifics about the interface modes 
Mode 1: Continuous 
 
Frame rate:
 Matrox Radient eCL receives the continuous video from the camera 
at 179.7 frames per second. 
 
Exposure time:
 Exposure time is set using the programmable exposure setting in 
the Camera Configuration utility. Refer to the camera manual for more 
information. 
Camera settings:
 Set the camera controls using the Flare utility as follows:  
‐ For 8tap – 8bit format: General Tab\Camera Link Output\Format\Full  
‐ For 10tap – 8bit format: General Tab\Camera Link Output\Format\Full‐80 (8‐bit) 
‐ Exposure Tab\Mode\Free‐Run, Programmable Exposure 
 
 
Mode 2: Pseudo‐continuous 
 
Frame rate:
 The frame rate is determined by the frequency of the TIMER1 OUT 
(CC1) signal. 
Exposure time
: The exposure time is determined by the pulse duration (high 
level) of the TIMER1 OUT (CC1) signal, which can be modified in the DCF using 
Matrox Intellicam or with the MIL MdigControl() function. Consult the respective 
manual for more information.  
Camera control settings:
 Set the camera controls using the Flare utility as follows: 
‐ For 8tap – 8bit format: General Tab\Camera Link Output\Format\Full  
‐ For 10tap – 8bit format: General Tab\Camera Link Output\Format\Full‐80 (8‐bit) 
‐ Exposure Tab\Mode\Edge‐Triggered, Level‐Controlled Exposure 
‐ Exposure Tab\Trigger 1\CC1 + High (Polarity)  
 
 
Mode 3: Asynchronous Reset
 
 
Frame rate
: The frame rate is determined by the frequency of the external trigger 
signal.  
Exposure time:
 Refer to Mode 2: Pseudo‐continuous.  
Camera settings:
 Refer to Mode 2: Pseudo‐continuous.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
RAD‐CID‐025 
Page 3 
 
Matrox Radient eCL     
Camera Interface Application Note
  
IO Industries Flare 4M180‐CL                   
July 23, 2013
 
 
 
Cabling Requirements 
Cabling details for the interface 
 modes 
Mode 1 and 2: Continuous and Pseudo‐continuous 
 
Cable and Connection:
 Two Mini‐To‐Mini Camera Link cables.  
 
Mode 3: Asynchronous Reset 
 
Cable and Connection:
 Two Mini‐To‐Mini Camera Link cables. 
External trigger:
 External trigger should be connected to the external auxiliary I/O 
(connector A on Matrox Radient eCL bracket). 
 
EXTERNAL AUX. I/O  
(connector A)                                                                            External Trigger Source
 
 
 
PIN NAME                                       PIN NO.                             PIN NAME                    PIN NO.
 
OPTO_AUX_IN0 +                          15                  
Å
                SIGNAL                              ‐‐ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
OPTO_AUX_IN0  ‐                          09                  
Å
                GROUND                          ‐‐ 
 
The DCFs mentioned in this application note are also attached (embedded) to this PDF file – use the Adobe Reader’s View File Attachment to access the 
DCF files. The information furnished by Matrox Electronics System, Ltd. is believed to be accurate and reliable. Please verify all interface connections with 
camera documentation or manual. Contact your local sales representative or Matrox Sales office or Matrox Imaging Applications at 514‐822‐6061 for 
assistance. © Matrox Electronic Systems Ltd, 2013.
 
Matrox Electronic Systems Ltd.
 
1055 St. Regis Blvd. 
Dorval, Quebec H9P 2T4 
Canada 
Tel: (514) 685‐2630 
Fax: (514) 822‐6273
 
 
RAD‐CID‐025 